Home > Engineering > FAQS > Electronic technique
How to calculate fan life utilizing L10 method?
2015-07-14 17:23:34 admin

Minimum service life (L10 Life):
   A: Minimum service life (L10 Life):
   T (forecast) = T (actual) x FCC

Where: 
   - T (forecast) = the forecasted L10 life under working temperature Tf usually 25oC.
   - T (actual) = the actual tested life under temperature Ta
   - FCC = temperature accelerator = 2 EXP[(Tf - Ta)/10 ]